ZS2 Pro Zone Sensor

BMS & Control Automated Logic SENSORS
ZS2 Pro Zone Sensor
COMMUNICATING

ZS2 Pro Zone Sensor

Advanced zone sensing with clear display and full occupant interaction
The ZS2 Pro Zone Sensor combines multi‑parameter sensing, a large easy‑to‑read display, and full occupant interaction controls, delivering enhanced comfort management, indoor air quality awareness, and seamless integration with Automated Logic systems.

Features

Modern, Professional Design

Contemporary styling that blends into commercial and institutional environments.

Comprehensive Sensing Options

Available sensing options include: Temperature Motion Relative humidity Carbon dioxide (CO₂) Volatile organic compounds (VOC)

Large LCD Display

Features a large, easy‑to‑read LCD screen for clear visibility of zone conditions and status.

Occupant Interaction Controls

Includes: Push‑button controls Setpoint adjustment Occupancy override button Occupancy status indicator Alarm indicator

Specifications

Sensing Performance

Temperature

Range (any option except humidity): 32°F to 122°F (0°C to 50°C)
Accuracy: ±0.35°F (±0.2°C)
Range (with humidity and any option): 50°F to 104°F (10°C to 40°C)
Accuracy: ±0.5°F (±0.3°C)

Humidity

Range: 20% to 80% RH
Accuracy: ±2% typical

Carbon Dioxide (CO₂)

Range: 400 to 2000 ppm
Accuracy: ±50 ppm + 2% of reading

Volatile Organic Compounds (VOC)

Range: 0 to 2000 ppm
Accuracy: ±100 ppm

Total Volatile Organic Compounds (TVOC)

Range: 125 to 600 ppb @ 77°F (25°C)
Accuracy: ±100 ppm

Particulate Matter (PM)

Range: 0 to 1000 µg/m³ (maximum)
Accuracy:

1–100 µg/m³: ±15 µg/m³
101–500 µg/m³: ±15%
(Measured at 25 ±2°C, 50 ±10% RH)

Motion Sensing

Sensor type: PIR
Detection distance: 16.4 ft (5 m)
Detection range (H × V): 100° × 82°
Movement speed: 2.62–3.94 ft/s (0.8–1.2 m/s)
Detection object size: 27.56 × 9.84 in (700 × 250 mm)

Power Requirements

12 VDC supplied by controller via Rnet
Power consumption varies by configuration:
Temperature only / Temperature + Humidity: 8 mA
Temperature + VOC / Temp + VOC + Humidity: 60 mA
Temp + CO₂ + Humidity: 15 mA (idle) to 190 mA (CO₂ cycle)
Temp + CO₂ + TVOC + PM + Humidity: 15 mA (idle) to 150 mA
Additional power may be required depending on configuration.

Communication

115 kbps Rnet communication between sensor and controller
Maximum 15 sensors per Rnet network
Maximum 5 sensors per control program

Technical Documents

Document Name Description Document Type Language Action
Spec Sheet (North America) ZS2 Pro Zone Sensor Spec Sheet (North America) PDF English Download
Spec Sheet (Europe) ZS2 Pro Zone Sensor Spec Sheet (Europe) PDF English Download

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.

    For more information : ahi@ahi-carrier.com