TruVu™ ChillerVu™ Plant Controller

BMS & Control Carrier i-Vu Building Automation Controllers
TruVu™ ChillerVu™ Plant Controller
Chiller Plant Optimization

TruVu™ ChillerVu™ Plant Controller

Centralized, intelligent control for high‑performance chiller plant operation
The TruVu™ ChillerVu™ Plant Controller (TV‑PSM) delivers advanced, scalable control for chilled water plants, combining optimized staging, pump and tower management, and open‑protocol integration within the Carrier i‑Vu® Building Automation System.

TruVu™ ChillerVu™ Plant Controller

The TruVu ChillerVu Plant Controller coordinates the functions of all main chiller plant components, providing optimized equipment operation while helping to reduce energy usage and operating costs. The system includes a dedicated chiller plant controller and an extensive library of control programs, graphics, and energy dashboards that can be easily customized to meet the design and specifications of any chiller plant.

The TV-PSM features built-in routing and integration capabilities, along with support for up to nine TruVu MPC I/O expansion modules and a total of 180 input/output points.

TruVu™ ChillerVu™ Plant Controller

Comprehensive Chiller Plant Control

Manages chillers, pumps, cooling towers, and auxiliaries using pre‑engineered plant control sequences.

Energy Optimization Strategies

Supports enhanced chiller staging, variable‑flow pump control, tower fan optimization, and demand limiting to reduce peak energy costs.

Open & Flexible Integration

Integrates with Carrier and third‑party plant equipment using BACnet® and Modbus® protocols.

Pre‑Configured Dashboards & Graphics

Includes ready‑to‑use energy dashboards, trends, alarms, and high‑quality plant graphics for immediate visibility.

Controller Type

BACnet Building Controller (B‑BC), BACnet Router (B‑RTR), and BACnet BBMD (B‑BBMD) compliant
(BACnet 135‑2012 Annex L, Protocol Rev. 14)

Communication Interfaces

Gigabit Ethernet for BACnet/IP, BACnet/Ethernet, and Modbus TCP/IP
Dual EIA‑485 ports for BACnet MS/TP or Modbus RTU
USB and service Ethernet ports for commissioning and recovery

Third‑Party Integration Capacity

Supports up to 1,500 BACnet points and 200 Modbus points

Power Requirements

24 VAC ±10% (50 VA) or 26 VDC ±10% (15 W), Class 2 power

Document Name Description Document Type Language Action
Brochure Carrier® ChillerVu™ Brochure PDF English Download
Product Data Carrier® TruVu™ ChillerVu™ Plant Controller Product Data Sheet PDF English Download
What is the primary role of the TV‑PSM controller?

It serves as the central controller for chilled water plants, coordinating chillers, pumps, towers, and auxiliary equipment.

Can the controller work with non‑Carrier chillers?

Yes. It supports third‑party chillers using BACnet or Modbus, provided the required points are accessible.

How does the controller reduce energy consumption?

Through optimized chiller staging, variable‑flow pumping, tower fan control, chilled water reset, and demand limiting strategies.

Is the controller customizable for different plant designs?

Yes. Control sequences and graphics can be edited using EquipmentBuilder and SNAP to match specific plant requirements.

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.