TruVu™ ChillerVu™ Chilled Water System Optimizer

BMS & Control Carrier i-Vu Building Automation Controllers
TruVu™ ChillerVu™ Chilled Water System Optimizer
Chiller Plant Optimization

TruVu™ ChillerVu™ Chilled Water System Optimizer

Intelligent chilled water optimization for maximum plant efficiency and performance
The TruVu™ ChillerVu™ Chilled Water System Optimizer (TV‑OPT) enhances chiller plant operation through advanced setpoint optimization, intelligent learning algorithms, and seamless integration with the Carrier i‑Vu® Building Automation System.

TruVu™ ChillerVu™ Chilled Water System Optimizer

The TruVu Chilled Water System Optimizer is a sophisticated, scalable, native BACnet optimization solution for chilled water plants. The TV-OPT minimizes the energy use of the entire chilled water system, up to and including airside equipment.

The factory-engineered control program is designed to provide advanced chilled water and condenser water setpoint reset, managing the plant chilled water supply temperature and the condenser water supply temperature to provide optimal energy usage while assuring occupant comfort in the building.

The TV-OPT provides seamless integration with the ChillerVu Plant System Manager and is compatible with plants consisting of Carrier 19, 23, or 30 series chillers (air or water-cooled). The system can also be applied to plants featuring third party equipment and controllers, providing the same optimization benefits as are possible with Carrier based plants. An integrated dashboard is also included, providing actionable intelligence to facilities staff, along with real time monitoring of the overall efficiency of the chilled water system, from anywhere at any time using the i-Vu building automation system.

TruVu™ ChillerVu™ Chilled Water System Optimizer

Advanced Chilled Water Optimization

Dynamically resets chilled water and condenser water setpoints to minimize energy consumption while maintaining comfort and system stability.

Intelligent Learning Algorithms

Continuously adapts to changing environmental conditions, mechanical performance, and facility usage patterns.

Seamless Chiller Plant Integration

Fully compatible with TruVu ChillerVu™ plant manager and plug‑and‑play with the Carrier i‑Vu® system.

Embedded Analytics & Visualization

Built‑in dashboards, trends, and alarms provide clear insight into plant performance, energy usage, and system efficiency.

Controller Type

BACnet Building Controller (B‑BC), BACnet Router (B‑RTR), and BACnet BBMD (B‑BBMD) compliant
(BACnet 135‑2012 Annex L, Protocol Revision 14)

Communication Interfaces

Gigabit Ethernet for BACnet/IP, BACnet/Ethernet, and Modbus TCP/IP
Dual EIA‑485 ports for BACnet MS/TP or Modbus RTU
USB port for service, recovery, and local display support

Third‑Party Integration Capacity

Supports up to 1,500 BACnet points and 200 Modbus points (memory dependent)

Power Requirements

24 VAC ±10% (50 VA) or 26 VDC ±10% (15 W), Class 2 power source

Document Name Description Document Type Language Action
Brochure Carrier® ChillerVu™ Brochure PDF English Download
Data Sheet Carrier® TruVu™ ChillerVu™ Chilled Water System Optimizer Product Data Sheet PDF English Download
What does the Chilled Water System Optimizer do?

It optimizes chilled water and condenser water setpoints to reduce energy consumption while maintaining plant performance and occupant comfort.

Does TV‑OPT work with non‑Carrier chillers?

Yes. It supports optimization of third‑party chiller plants using BACnet and Modbus® protocols.

How does the optimizer adapt to changing conditions?

It uses intelligent learning algorithms that continuously adjust to ambient conditions, equipment behavior, and facility load changes.

Can operators easily view plant performance?

Yes. The system includes intuitive dashboards showing energy usage, kWh, kW demand, tonnage, and kW/ton efficiency.

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.