Chilled Water System Optimizer

BMS & Control Automated Logic BUILDING CONTROLLERS
Chilled Water System Optimizer
CENTRAL PLANT CONTROL

Chilled Water System Optimizer

System‑level optimization for reducing total chilled water energy consumption
The Chilled Water System Optimizer intelligently minimizes energy use across the entire chilled water system by continuously optimizing plant and air‑side operation based on real‑time conditions.

Chilled Water System Optimizer

The OptiFlex chilled water system optimizer is a sophisticated, scalable, native BACnet optimization solution for chilled water plants. The chilled water system optimizer minimizes the energy use of the entire chilled water system, up to and including air handling units and other water side chilled water consumers. By providing optimized control of the chilled water and condenser water setpoints, the chilled water system optimizer can lower energy costs while also maintaining occupant comfort levels in the building. The chilled water system optimizer solution consists of a self-adapting control algorithm packaged in an application specific Automated Logic controller.

Chilled Water System Optimizer

Designed for Variable Plant Sizes

Engineered for chilled water plants of varying sizes, supporting configurations with up to eight chillers.

Adaptive Optimization Logic

Automatically adapts to changing environmental conditions and system changes over time, maintaining optimized performance without manual retuning.

Integrated Optimization Dashboard

Monitors and displays optimization performance metrics through an integrated dashboard.

Lower First Cost

Provides a lower first cost compared to solutions that require extensive plant analysis, system modeling, or major mechanical and control upgrades.

Plant Capacity Support

The optimizer is designed for chilled water plants with up to eight chillers, accommodating a wide range of system sizes.

Optimization Scope

The system can operate on the chilled water loop, the condenser water loop, or both, depending on plant configuration and optimization goals.

System Integration

The optimizer integrates as a supervisory layer to existing plant control systems, computing optimal setpoints without replacing core plant controls.

Energy Monitoring

The system continuously monitors plant room energy consumption and load‑side energy usage to drive optimization decisions.

Document Name Description Document Type Language Action
Spec Sheet Chilled Water System Optimizer Spec Sheet PDF English Download
What is the primary purpose of the Chilled Water System Optimizer?

It reduces total chilled water system energy consumption by optimizing plant and air‑side operation in real time.

Does the optimizer replace existing plant controls?

No. It integrates with existing plant control systems and operates as an optimization layer.

What happens if optimization cannot be calculated?

The system automatically reverts to default setpoints using built‑in fail‑safe logic.

Does it support future expansion or plant changes?

Yes. The optimizer adapts automatically to system changes and evolving operating conditions.

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.

    For more information : ahi@ahi-carrier.com