i-Vu® VVT Bypass II Controller

BMS & Control Carrier i-Vu Building Automation Controllers
i-Vu® VVT Bypass II Controller
Zoning Controllers

i-Vu® VVT Bypass II Controller

Reliable bypass control for stable, energy‑efficient VVT system performance
The i‑Vu® VVT Bypass II Controller (OPN‑VVTBP‑02) provides factory‑engineered control for VVT bypass applications, delivering accurate pressure regulation, equipment protection, and seamless integration with the Carrier i‑Vu® Building Automation System.

i-Vu® VVT Bypass II Controller

Product Integrated Controller
The VVT Bypass II controller is used to regulate the supply duct static pressure for a variety of pressure-dependent VVT applications and allows constant volume HVAC equipment to provide zone level temperature control. This advanced controller features a separable, brushless actuator and an integral pressure sensor for reliability and longevity. It also features native BACnet communications and plug-and-play connectivity to the Carrier i-Vu Building Automation System.

i-Vu® VVT Bypass II Controller

Advanced Bypass & Pressure Control

Factory‑engineered control programs ensure reliable, energy‑efficient bypass operation with automatic pressure sensor calibration.

Discharge Temperature Protection

Built‑in temperature protection minimizes air‑source heating or cooling lockouts caused by unacceptable discharge temperatures.

Flexible Airside & VFD Control

Supports 0–10 VDC VFD output for drive speed modulation and can control multiple damper actuators.

Integrated Actuation & Sensing

Includes a separable brushless actuator and integral precision pressure sensor for accurate, dependable bypass control.

Controller Type

BACnet Advanced Application Controller (B‑AAC)
(BACnet 135‑2012 Annex L, Protocol Revision 9)

Communications

BACnet MS/TP via EIA‑485 or ARCNET (DIP‑switch selectable)
Local access port for startup and troubleshooting (115.2 kbps)

Inputs & Outputs

1 analog input: Discharge Air Temperature (10k thermistor)
1 analog output: 0–10 VDC for VFD or actuator control

Actuator & Pressure Sensing

Brushless DC actuator, 45 in‑lb torque, 205‑second runtime (90° travel)
Integral pressure sensor: 0–2 in. H₂O, ±5% accuracy at full scale

Document Name Description Document Type Language Action
Brochure VVT Zoning System Brochure PDF English Download
Data Sheet i-Vu Open VVT Bypass II Controller Product Data Sheet PDF English Download
What is the primary role of the VVT Bypass II Controller?

It regulates bypass airflow to maintain stable duct pressure and protect VVT airside equipment during changing zone demand conditions.

How does the controller help prevent system lockouts?

Discharge temperature protection logic minimizes heating or cooling lockouts caused by unsafe air temperatures.

Does the controller include pressure sensing?

Yes. A built‑in precision differential pressure sensor measures airflow pressure accurately.

Who should choose i‑Vu VVT Bypass II?

Facilities that need:

stable VVT system pressure control
reduced airside lockouts
energy‑efficient bypass operation
open BAS integration
seamless i‑Vu system compatibility

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.

    For more information : ahi@ahi-carrier.com