i-Vu® VVT Zone II Controller

BMS & Control Carrier i-Vu Building Automation Controllers
i-Vu® VVT Zone II Controller
Zoning Controllers

i-Vu® VVT Zone II Controller

Reliable, pressure‑dependent zone control for efficient VVT applications
The i‑Vu® VVT Zone II Controller (OPN‑VVTZC‑02) provides factory‑engineered, energy‑efficient control for VVT zone applications, combining advanced comfort management, flexible heating options, and seamless integration with the Carrier i‑Vu® Building Automation System.

i-Vu® VVT Zone II Controller

The VVT Zone II controller provides zone level temperature and air quality control for a variety of pressure-dependent VVT applications. This advanced controller features a separable actuator for easy installation onto single duct and parallel fan-powered air terminals. It also features native BACnet communications and plug-and-play connectivity to the Carrier i-Vu Building Automation System.

i-Vu® VVT Zone II Controller

Pressure‑Dependent Zone Control

Factory‑engineered control algorithms deliver stable and efficient regulation of space temperature in VVT systems.

Flexible Heating Support

Supports modulating or two‑position hot water, multi‑stage electric heat (up to three stages), and zone perimeter heating.

Advanced Comfort & Ventilation Routines

Built‑in routines support zone‑level humidity control and demand‑controlled ventilation (ASHRAE® 62).

Seamless i‑Vu Integration

Fully plug‑and‑play with the Carrier i‑Vu® Building Automation System, including integrated Carrier airside linkage algorithms.

Controller Type

BACnet Advanced Application Controller (B‑AAC)
(BACnet 135‑2012 Annex L, Protocol Revision 9)

Communication Protocols

BACnet MS/TP via EIA‑485 or ARCNET (selectable)

Inputs & Outputs

3 analog inputs (RH/CO₂, room temperature, supply air temperature)
1 binary input (remote occupancy)
1 analog output (0–10 VDC hot water valve)
3 binary outputs (heating stages and fan)

Power Requirements

24 VAC ±10%, 50/60 Hz (14 VA) or 26 VDC
Class 2 power source only

Document Name Description Document Type Language Action
Brochure VVT Zoning System Brochure PDF English Download
Product Data i-Vu Open VVT Zone II Controller Product Data Sheet PDF English Download
What type of VVT systems is this controller designed for?

It is designed for pressure‑dependent VVT zone applications, providing reliable zone‑level temperature control.

How does this controller differ from VAV zone controllers?

Unlike VAV controllers, this controller regulates airflow indirectly through pressure‑dependent VVT operation, making it suitable for VVT architectures.

Can the controller support different heating configurations?

Yes. It supports hot water heating, multi‑stage electric heat, and zone perimeter heating.

How does the controller support energy savings?

Energy efficiency is achieved through demand limiting, adaptive optimal start, and factory‑engineered control logic.

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.

    For more information : ahi@ahi-carrier.com