i-Vu® UPC Open

BMS & Control Carrier i-Vu Building Automation Controllers
i-Vu® UPC Open
Networking and Integration

i-Vu® UPC Open

Factory‑ready BACnet connectivity for Carrier equipment with seamless i‑Vu® integration
The i‑Vu® UPC Open (OPN‑UPC) provides pre‑engineered, plug‑and‑play BACnet connectivity for Carrier rooftop units and chillers, enabling fast commissioning, built‑in diagnostics, and seamless integration with the Carrier i‑Vu® Building Automation System.

i-Vu® UPC Open

Integrated BACnet® Communications Card
Connecting your Carrier equipment to a BACnet MS/TP network has never been easier. Simply connect the UPC Open to the BACnet network, and your Carrier equipment is ready to integrate seamlessly into the i-Vu Building Automation System or any other BACnet Building Automation System.

i-Vu® UPC Open

Native Equipment Integration

Factory‑installed option on Carrier rooftops, air‑cooled chillers, and water‑cooled chillers.

BACnet‑Ready Out of the Box

Pre‑programmed to share equipment data with any BACnet BAS—no on‑site engineering required.

Integrated i‑Vu Connectivity

Plug‑and‑play connection to the i‑Vu system with: Integrated air‑source linkage algorithm Built‑in graphics, trends, and alarms Demand limiting support Native compatibility with i‑Vu Tenant Billing

Local Sensor & Display Support

Supports Carrier communicating space sensors, ideal for single‑zone rooftop applications.

Communication Ports

BAS Port (Port 1A): EIA‑485 for BACnet MS/TP (Modbus and future N2 support)
Rnet Port: For Carrier communicating space sensors
Local Access Port: For startup and troubleshooting (115.2 kbps)
LON‑OC Port: Future option for LON connectivity

Clock & Power Backup

Battery‑backed real‑time clock
10‑year CR2032 lithium battery (minimum 10,000 hours of trend and time retention)

Power Requirements

24 VAC ±10% (10 VA) or 26 VDC
Class 2 power source only

Environmental Ratings

Operating: ‑22°F to 150°F (‑30°C to 66°C), 10–95% RH non‑condensing
Storage: ‑24°F to 140°F (‑30°C to 60°C)

Document Name Description Document Type Language Action
Installation Guide UPC Open Installation and Start-up Guide PDF English Download
Product Data i-Vu Open UPC Open Factory Installed Product Data Sheet PDF English Download
What is the primary role of UPC Open?

It provides factory‑installed BACnet connectivity for Carrier HVAC equipment, enabling fast integration with i‑Vu and other BACnet systems.

Does UPC Open require custom programming on site?

No. It is pre‑programmed at the factory, eliminating the need for on‑site engineering in most applications.

Which types of equipment support UPC Open?

Carrier rooftops, air‑cooled chillers, and water‑cooled chillers with factory or field‑installed UPC Open options.

Can UPC Open support local zone control?

Yes. It supports Carrier communicating space sensors and is well suited for single‑zone rooftop applications.

Similar Products

How Can We Help?

Have a question that doesn’t fit a specific category? Reach out to our team here for all other support
and information

    Become a Dealer

    Get directed to our Business Development team to start the authorization process and discuss sales support.

    Technical Assistance

    Get specialized help with system sizing, load
    calculation analysis, and technical data required for project design.

    Aftermarket Service

    Request support for warranty claims,
    scheduled maintenance, and genuine spare
    parts ordering.

    For more information : ahi@ahi-carrier.com